Rinnai Tankless Water Heater Beeping—What’s Wrong?

Rinnai Tankless Water Heater Beeping—What’s Wrong?

Rinnai water heaters provide homeowners and guests with hot water when required. This sanitary device works well most of the time, but it can sound an alarm in certain situations. But what is the issue if the Rinnai Water Heater alarm goes off? We conducted some research for you and discovered this solution.When an error occurs, the Rinnai water heater alarm can beep indefinitely. Error codes 2-79 are among the possible errors. Certain events may cause the error code to appear on the device display alongside other letters rather than numbers. The error code LC0 is an example. It indicates that the water heater has detected scale buildup.

You investigate the root cause and ensure that users do not make errors when troubleshooting. Continue reading for more information on these error codes. It also describes troubleshooting Rinnai water heaters when they develop specific errors.

Also check: Water Heater Temperature Sensor Failure—What to Do?

ImageProductFeaturesPrice
Best Seller
Tankless gas water heater: Endless hot water, energy-efficient, optimal pressure, warranty.
Rinnai V53DeP Tankless Hot Water Heater, 5.3 GPM, Propane,

Tankless gas water heater: Endless hot water, energy-efficient, optimal pressure, warranty.



$636.22
Best Seller
Tankless propane water heater: Compact, durable, smart design,
Rinnai RL75IP Tankless Hot Water Heater, 7.5 GPM, Propane,

Tankless propane water heater: Compact, durable, smart design,


$927.89
Best Seller
Natural Gas or Propane Tankless Water Heater, Indoor or Outdoor Water Heater, Up to 11.1 GPM, 199,000 BTU
Rinnai RXP199iN Condensing Smart Sense Natural Gas 

Natural Gas or Propane Tankless Water Heater, Indoor or Outdoor Water Heater,


$2,407.40
Best Seller
Super High Efficiency Plus Propane Heater, Up to 11 GPM, Indoor Installation, 199,000 BTU
Rinnai RSC199iP Smart-Circ Condensing Gas Tankless Water Heater

Super High Efficiency Plus Propane Heater, Up to 11 GPM, Indoor Installation, 199,000 BTU



$1,680.21
Best Seller
 Tankless Water Heater, Up to 5.3 GPM, Outdoor Installation, 140,000 BTU
Rinnai RE140eP Non-Condensing Propane Tankless Water Heater

 Tankless Water Heater, Up to 5.3 GPM, Outdoor Installation, 140,000 BTU

 $725.13

What causes the Rinnai water heater to beep?

Rinnai water heaters can emit an alarm when they encounter various bugs. These are some of the error codes and their meanings:

  • Error code 02 indicates that the water heater is not in anti-freeze mode.
  • Avoid servo malfunction with error code 05.
  • The exhaust or air supply has been disconnected, resulting in error code 10.
  • The water heater cannot be ignited, resulting in error code 11.
  • Error code 31: A temperature sensor failure error has been detected.

Understanding these error codes will enable Rinnai water heater owners to pinpoint specific problems. The user can use the appropriate procedure to repair, repair, or replace specific parts.

Some error codes, such as Error code 30, indicate that the unit detected flammable gas and typically necessitates professional troubleshooting and repair. Inexperienced DIYers should not attempt to overcome these concerns. Other accidents can be hazardous to your health and cause permanent damage to your vehicle.

What does the error code LC0 for Rinnai water heaters mean?

A flashing LC0 (maximum LC9) error code on the Rinnai Instant Water Heater display indicates a scale buildup. The owner should consult the product’s instruction manual to remove this substance and reactivate the device.

How do you fix a Rinnai water heater problem?

The troubleshooting steps needed to clear the Rinnai Instant Water Heater alarm will vary depending on the error code and the specific problem you are experiencing. For example, code 03 indicates that the water heater failed when the unit attempted to fill the bath during a power outage. The user reset the system by pressing the ON / OFF button twice. On the other hand, an error code usually necessitates additional steps to turn off the beep and restore the device’s proper operation.

Here’s how to clear the outlet or air supply blockage that caused error code 10 on your Rinnai water heater.

Step-by-step guide

  • Remove the vent from the Rinnai water heater’s top. Then test to see if you can turn on the device without venting. In this case, the issue is frequently in the vent line installation.
  • Continue troubleshooting by going over each ventilation section again. Check that each component’s mounting and mounting depth are correct.
  • Examine each gap. If intervals are not installed, flammable gas may circulate inside the water heater.
  • Check that the DIP switches are correctly installed. This component must be at a 90-degree angle for each vent length count.
  • Examine the vent system for dirt. Remove any substances that may be causing the error code.
  • Check that the vent port is not incorrectly turned, overhanging, or obstructed.

Remember that clogging the water heater’s air inlet or outlet may not be the primary cause of the unit’s alarm. A short circuit in the fan motor, wire harness, or circuit board could also cause the team to display error code 10.

Is your water heater blinking red light? Learn about it all here at Rheem water heater blinking red light.

How do I reactivate my Rinnai water heater?

Resetting the Rinnai water heater can turn off the constant beep, especially if an error code such as 03. To soft reset this hot water system, do the following:

  1. Turn off all water heater-connected appliances, such as bathtubs and faucets.
  2. Twice press the ON/OFF button.
  3. Turn on the water heater and perform a test.

Remember that resetting the Rinnai water heater may necessitate several attempts before the process yields the desired results.

How do I resolve the Rinnai water heater beep without a fault code?

Assume your Rinnai instant water heater does not display an error code. In this case, the alarm beeps but does not function. You can begin the repair by disconnecting and reconnecting the device from the appropriate power source. If turning the device on and off does not resolve the problem, proceed with the troubleshooting and remediation steps below.

  • Turn off the cold water but leave the hot water running.
  • Drains the system’s hot water. After that, unplug the cold-water valve.
  • Clean the screen that is covered by the plug.
  • If the device does not work in this step, repeat steps 1-3, but this time drains the cold water.
  • Place cold and hot water in separate containers. Restore power to the device and test it to see if the problem persists.

The problem may not be resolved at this point. Even in this case, the Rinnai water heater can be restored to working order. This time, however, you will require an air compressor. Once you’ve obtained this device, follow these steps to secure your sanitary ware.

  1. Check that the cold and hot water is turned off and that the faucet tank is empty.
  2. Remove the screw from above the cold-water valve plate. Set the plate aside once it is loose.
  3. Spray the water heater through the air compressor’s hole. If you hear a whirling sound, it means it’s working.
  4. Cover the holes with a plate and screw them shut.
  5. Check if the beep stops and the device’s functionality is restored.
  6. If your Rinnai water heater is still not working, we recommend contacting the manufacturer or a certified technician for service.

Also check: Are Furnace Blower Motors Interchangeable?

Rinnai should be set to what temperature?

To avoid burning the water in the bath, set the Rinnai water heater to 120 degrees Fahrenheit. However, if desired, some users can raise the temperature to 140 degrees Fahrenheit. To finish this task, follow the steps below.

  1. Turn off the water heater’s power supply.
  2. Remove the front cover.
  3. Locate DIP switch six and toggle it to the on position. This step may necessitate the use of a small screwdriver.
  4. Replace and repair the front cover. The power of the water heater should then be restored.

Please keep in mind that prolonged soaking in hot water can be harmful to your health. Dry skin and weakened immunity are two of these risks. Furthermore, it is recommended that the water heater be used for an average of 3-5 hours per day.

What is causing my Rinnai Tankless Water Heater Beep?

Rinnai water heaters usually continue to beep due to an error. The error codes displayed on these sanitary fixtures’ screens should help pinpoint the source of these issues. The owner can restore these hot water systems to working order with proper troubleshooting and repair techniques.

YOU MIGHT ALSO LIKE

About Author

Mobeen Shahid

Mobeen Shahid

Mobeen Shahid is a Mechanical Engineer with two years of experience in the HVAC industry. His passion is analyzing HVAC issues, and he works relentlessly to devise customized solutions. He has been in the industry long enough to know the ins and outs and ensures that areas are optimally heated, cooled, and ventilated.

Must Have Tools For HVAC Tech

Newsletter

Stay updated on HVAC insights. Subscribe now!

Recent Posts