How To Troubleshoot Rinnai Error Code 17?

How To Troubleshoot Rinnai Error Code 17?

Rinnai Error Code 17 indicates a problem with the temperature sensor in your water heater. If the heater’s sensor is not properly calibrated or there is debris buildup on the sensor, error code 17 will appear.

Any debris that accumulates on the sensors may impair their performance. It could cause your water heater to overheat, resulting in irreversible damage.

Rinnai error code 17 does not appear on all Rinnai models. Only Rinnai units with venturi controls and switches are susceptible to fault code 17. Fixing error code 17 is quick, simple, and takes minimal time.

You can accomplish it independently as a beginner or a seasoned professional. So, you’re probably wondering what needs to be done to resolve Rinnai problem code 17. To fix Rinnai error code 17, clean and remove any build-ups or restrictions obstructing the venturi. Continue reading for a comprehensive troubleshooting guide.

Rinnai Error Code 17 Troubleshooting.

Reboot The System.

Disconnect all system devices and wait for 30 seconds before proceeding. Once everything is confirmed to be plugged in, power on the system and access the BIOS configuration utility. Navigate to the restart option in the menu and choose “Restart immediately.” The system will then restart automatically after updating the system password.

Turn Off The Water Heater For 5 Minutes.

Stop the water heater supply by closing the main valve. Unplug the water heater to turn it off. Remove the water heater cover and unhook the intake pipe. When shutting off the hot tub, disconnect the gas feed to the water heater and check for leaks.

Remember to reconnect the drains after replacing the water heater panel. Before using the water heater, fill its gas tank and change the steam valve.

Replace Your Water Heater.

Turn off the water heater by pulling the plug and removing the lid. Before recharging the water heater, wait three minutes after turning it off. This is when you can scrape the spark plug.

After the three-minute delay, connect the tubes after setting up the igniter. Upgrading your water heater may be a wise update for efficiency and performance.

Also, Read: Rinnai Error Code 12: Troubleshooting the Water Heater.

Check For Leaks In The Gas Line.

Turn off all electrical devices and turn on the main light to look for gas leaks. Check for any smoke or sparks from the device to ensure no gas leak. Turn off the main switch and contact a professional if you smell gas. A leak in a line can be found using a meter. Stop gas flow into the house and examine the meter line for leaks. If the pipe pressure is too low, there may be a leak. High pressure usually indicates that a line is in good condition. When a line springs a leak, it needs to be replaced.

How To Fix Gas-Related Problem Causing Error Code 17?

  • First, ensure your tankless device has a steady gas supply.
  • You must also confirm that the gas type matches the rating plate on your tankless unit.
  • Simply set the dip switch on the electronic board of your propane tankless unit or any other variant to the correct type.
  • Furthermore, the gas pressure must be aligned in accordance with the rating plate.
  • There could be several causes for low gas pressure, including the faulty size of the gas system, failure to meet manufacturer specifications, and, most critically, filth and debris.
  • After the installation, the air must be purged from the gas lines to avoid any last-minute mishaps.
  • If you are unsure about repairing the problem yourself, the best thing you can do is call a licensed specialist who will save you time and keep you from being exposed to dangerous gases, etc.

How To Repair The Igniter Problem Causing Rinnai Error Code 17?

  • First and foremost, you must examine the ignitor’s condition.
  • All you have to do is cycle your tankless unit and look for a spark.
  • If there is a spark, you’re on the right track; otherwise, look for a loose connection and, if present, a damaged element.
  • Cross-check the correct voltage on the electric board when your tankless unit is in the ignition cycle.
  • To position the igniter appropriately, tightly tighten it and its ceramic insulation to the mounting bracket.
  • The biggest issue with a Loose Rod is that it can create no sparks or sparks that last for a shorter period if it comes into touch with other metal components.
  • If you intend to replace an element, you must replace the gasket.
  • To avoid any last-minute mishaps, examine the igniter and clean any carbon or scale accumulation as stated in the handbook.

Conclusion.

In conclusion, when repairing the Rinnai Error Code 17, you should be patient and methodical. If you meticulously follow the instructions, you should be able to discover and resolve the underlying issues, restoring the tankless water heater to peak performance.

A well-maintained, energy-efficient machine that reliably dispenses hot water necessitates routine maintenance and the prompt eradication of error codes. Contact a Rinnai service technician if you discover problems that are outside the scope of these instructions.

FAQ.

How can the Rinnai error code be removed?

  • The unit’s on/off switch is located on the temperature controller.
  • Five times must be pressed on the on/off button in five seconds.
  • The water heater will be reset once the error message has been cleared.

Why does the water heater need to be reset?

If your water heater loses power, you can restart it by pressing the reset button. Your device’s reset button, on the other hand, serves as a safety feature, turning it off if the water temperature rises too high.

YOU MIGHT ALSO LIKE

About Author

Mobeen Shahid

Mobeen Shahid

Mobeen Shahid is a Mechanical Engineer with two years of experience in the HVAC industry. His passion is analyzing HVAC issues, and he works relentlessly to devise customized solutions. He has been in the industry long enough to know the ins and outs and ensures that areas are optimally heated, cooled, and ventilated.

Recent Posts

The Best Basic Home Tools kits

Newsletter

Stay updated on HVAC insights. Subscribe now!